CGS Forming gas set

Set for pressure testing the high-pressure side of R134a systems with forming gas

Part no.: 6520010080

Further information

Included in delivery:
• Pressure reducer 20 bar
• Additional pressure gauge for monitoring pressure
• Bottle cart for 10 l bottles
• Yellow hose, 1.8 m HS6Y (connection of pressure reducer to additional pressure gauge)
• Red hose, 1.5 m HS5R (connection of additional pressure gauge, bottom to air conditioning system)
• High-pressure quick coupling
• Leak detection spray 400 ml
Adjustment range (bar):
0 - 20
Length of service hoses (m):
1,5 / 1,8
Weight:
11,65 kg
EAN codes:
4250675620645
Catalogue:
Electrics (p. 1587)
To be found in category:
ElectricsAir conditioning technologyGRANIT workshop equipment and accessoriesForming gas set
When pressure testing cold/air conditioning systems with forming gas, it should be noted that hydrogen (H2) is combustible . Therefore, only use forming gas with 95% nitrogen (N2) & 5% hydrogen (H2). Depending on the manufacturer, pressure testing takes place between 5 bar and 30 bar (pressure reducers up to 20 bar and up to 40 bar). The leakage is sought with a leakage search spray.
Original spare part numbers are for comparison purposes only. All prices are in €, excl. VAT. Errors reserved. Delivery subject to availability.